Measurement System Analysis – Going Beyond Audits – Highlights from the 2025 AIAG Quality Summit

Measurement System Analysis (MSA)

Measurement System Analysis – Going beyond Audits

SimpleQuE Consultant, Paul Gambino, recently attended the 2025 AIAG Quality Summit in Novi, MI. Themed “Driving Automotive Quality Forward: Innovating and Elevating Standards,” the event hosted by the Automotive Industry Action Group (AIAG), explored how AI is reshaping automotive quality, and also addressed IATF 16949®, the Red Supplier Process, Measurement System Analysis (MSA), QMS audits, software quality, and more. In this and future articles Paul will provide highlights and helpful insights for automotive suppliers.

MSA – An underutilized, yet valuable quality tool

One of the sessions Paul attended was titled “MSA Beyond Audits” presented by Nanda Kumar Ramakrishnan founder of PQSI (www.pqssi.co.in) in India.  Measurement System Analysis (MSA – IATF 16949®clause 7.1.5.1.1) is a leading cause of nonconformities (#4 of the top five IATF 16949® NCs).  Companies that are implementing IATF 16949® must meet this resource-intensive requirement which is actually an underutilized, yet valuable, quality tool.

Nanda started off with a quote from Dr. Deming – “Any technique can be useful if its limitations are understood and observed” to illustrate his first point, Why MSA?  That quote is a good description of the purpose of MSA: which to understand the variation due to the measurement system and separate it from the process variation.  Nanda also pointed out the difference between calibration, which assesses the accuracy of the measurement device, and MSA. 

His next point was an important one – When MSA?  It should not be “Less than one week before the IATF or a customer audit,” but rather, as per the MSA plan, when changes occur in any of the measurement system “SWIPE” elements (i.e., Standard, Workpiece, Instrument, Person and Procedure, or Environment – see MSA4, p. 16), or because of a customer complaint regarding form, fit or function. 

Nanda’s third point was regarding the interpretation of the results of a MSA GR&R (Gage Repeatability and Reproducibility) Study.  This goes beyond acceptability (e.g., GR&R % Study or Tolerance< 10%, ndc >= 5) to learn about appraiser bias or inconsistency, issues with the sample, etc., that can lead to improvements in the measurement system. 

The fourth point he touched on had to do with common misunderstandings involving MSA studies, such as replicable vs. non-replicable measurement systems, and choosing among tolerance, sample variation or estimated process standard deviation. 

Finally, his fifth topic consisted of five suggestions for Measurement System Analysis:

  • promote the use of control charts in MSA,
  • development of an MSA plan based on Critical to Quality (CTQ) parameters rather than instruments,
  • promotion of stability studies for lab equipment, such as CMM,
  • looking for improvement opportunities after an MSA study,
  • and requesting that AIAG publish an FAQ on MSA.

There was one question at the end of the session which seemed to relate to the hard requirement (i.e., “shall”) in the IATF 16949® clause 7.1.5.1.1 for MSA studies on each type of measuring, inspection and test equipment referenced on the control plan with the concept of an MSA plan prioritized based on CTQ characteristics.  Due to time constraints, this discussion carried over after the session was over. Paul noted that the prioritization of MSA studies based on CTQ characteristics is consistent with the note (which is guidance only, not a requirement) in clause 7.1.5.1.1 “that prioritization of MSA studies should focus on special …characteristics.”

That said, not having at least one MSA study for each type of measurement system referenced on the control plan (including attribute gages and visual inspection) will likely result in a finding.  If you have marginal results on several measurement systems, however, prioritizing your efforts based on special product or process characteristics is a good strategy.  Nanda’s point was that MSA studies take time to conduct properly, and prioritized improvement and reduced variability should be a goal of the effort expended, not just having a study to show an auditor.

More AIAG Quality Summit highlights

Keep on track as Paul covers more interesting automotive quality topics and summaries in other simpleQuE blogs:

Paul Gambino, is a simpleQuE consultant and auditor with more than 20 years’ experience implementing, maintaining and improving automotive quality management systems and business processes. He is also currently an ISO 9001 and IATF 16949® lead auditor for several Certification Bodies. 

We Can Help: IATF 16949® Experts a Click Away

If you’re searching for an IATF 16949:2016 consultant, our team at simpleQuE is well-positioned to support your IATF 16949® and MAQMSR consulting (Minimum Automotive Quality Management System Requirements), certification, maintenance, training and internal auditing needs. Our consultants are qualified, certified, and are experts on the automotive standards, customer-specific requirements, and AIAG or VDA core tools.

SimpleQuE also offers a full line-up of IATF 16949® training courses which includes AIAG and VDA Core Tools, Root Cause Analysis and Problem Solving, Requirements and Implementation.  With IATF® also putting a major focus on internal auditor competency, it is essential to have IATF 16949® Internal Auditor Training. Our IATF 16949® auditor training utilizes the process audit approach. Contact our IATF® consultants to learn more about the customized services offered to match your certification and training needs.

SimpleQuE is not associated with the IATF®, IAOB, ANAB®, IAQG®, and is not a certification body. SimpleQuE is an independent ISO 9001 certified, consulting, training, and second-party auditing service provider that assists a company on a path for the company to obtain and maintain certification through accredited certification bodies.

 

Learn More About The simpleQuE Advantage

The simpleQuE Advantage Begins Here! Contact Us Today